SPEC | VALUE |
---|---|
Accuracy by component | ±0.5%/F.S (range≧50), ±1%/F.S (5<range<50), ±2%/F.S(range≦5%) |
Accuracy by heating value | +/- 0.25 Btu/scf per 1000 Btu/scf |
Repeatability | +/- 0.25 Btu/scf per 1000 Btu/scf |
Sensitivity | 200 ppm |
Linearity | +/- 2% F.S. |
Response time | 4 to 5 minutes |
Ambient temperature | -20°C to + 60°C (-4°F to 140°F) |
Dimensions | 686 mm W x 838 mm H x 318 mm D (27” W x 33” H x 12.5” D) |
Weight | Division 1: 54.4 kg (120 lbs) Division 2: 38.6 kg (85 lbs) |
Power and consumption | 24 VDC, 100 watts startup, 50 watts running 90-240 VAC, 50/60 Hz 100 watts startup, 50 watts running |
Sample flow | 100 cc/min, 1 barg (0.21 SCFH, 15 psig) |
Gas requirements | Helium or hydrogen carrier gas 5.5 - 6.9 barg, 20 cc/min (80 - 100 psig, 0.042 scfh) |
Digital Outputs | Modbus RS232, Modbus RS485, Modbus TCP/IP |
Digital Inputs | 2 dry contact, 2 wet contact (12/24 VDC) |
Analog Inputs | 3 universal inputs, user programmable (RTD, 4-20 mA, transducer) |
Analog Outputs | 4 x 4-20 mA, user scalable, user selectable loop or self powered |
Relays | 4 x SPDT relays, 8 amp @250 VAC |
Approvals and Certifications | CSA (C, CUS) Class 1 Division 1, Groups BCD CSA (C, CUS) Class 1 Division 2, Groups BCD Measurement Canada for Custody Transfer |
Galvanic’s third-generation Btu and hydrocarbon gas chromatograph, the AccuChrome analyzer is designed and built for critical process-monitoring and control applications in the harshest environments. Whether you’re performing Btu and constituent analysis of natural gas for custody transfer, process optimization during natural gas fractionation, or 40 CFR 60 Subpart JA flare-gas emissions monitoring for regulatory compliance – you need precise, real-time measurements you can count on.
With auto calibration and validation capabilities to enable fully hands-off operation and the utmost in ease-of-operation, consistent, field-proven performance – and value, Galvanic’s AccuChrome analyzer can help you optimize your processes for better quality and lower costs. On rare occasions when there is a problem, it’s easy to address right then and there – the design enables ready access to all components, each of which are fully field-serviceable – reducing downtime and the need for costly module replacement.